SA'ADATUN NISA' (2022) PENGARUH PERBEDAAN TINGKAT KARAT PADA KUAT LENTUR PRE-KOROSI BETON DENGAN CANGKANG KELAPA SAWIT DAN SERAT MASKER. S1 thesis, Universitas Muhammadiyah Yogyakarta.
|
Text (Halaman Judul)
Halaman Judul.pdf Download (2MB) |
|
|
Text (Lembar Pengesahan)
Lembar Pengesahan.pdf Restricted to Registered users only Download (279kB) |
|
|
Text (Abstrak)
Abstrak.pdf Restricted to Registered users only Download (12kB) |
|
|
Text (Bab I)
Bab I.pdf Download (26kB) |
|
|
Text (Bab II)
Bab II.pdf Restricted to Registered users only Download (1MB) |
|
|
Text (Bab III)
Bab III.pdf Restricted to Registered users only Download (1MB) |
|
|
Text (Bab IV)
Bab IV.pdf Restricted to Registered users only Download (729kB) |
|
|
Text (Bab V)
Bab V.pdf Restricted to Registered users only Download (10kB) |
|
|
Text (Daftar Pustaka)
Daftar Pustaka.pdf Restricted to Registered users only Download (17kB) |
|
|
Text (Lampiran)
Lampiran.pdf Restricted to Registered users only Download (1MB) |
|
|
Text (Naskah Publikasi)
Naskah Publikasi.pdf Restricted to Registered users only Download (671kB) |
|
|
Text (Full Text)
Full Text.pdf Restricted to Repository staff only Download (7MB) |
Abstract
Utilization needs to be done to reduce environmental pollution due to palm oil shell waste, namely: one of them is replacing some of the coarse aggregates with oil palm shells in the concrete mixture. In this study, the percentage of oil palm shells used was 10%, and this value has been used in several previous studies as the optimum value. Concrete with palm kernel shells usually has a low flexural strength, so it is necessary to add additional mask fiber material to strengthen the concrete so that it has a high flexural strength value. In addition, concrete with palm oil shells and mask fibers needs to be reviewed under rusty conditions to determine the performance of the concrete in rusty conditions. This study used 14 specimens in the form of a beam with 10 x 10 x 50 cm with reinforcement with a diameter of 12 mm consisting of 4 normal specimens (0% corrosion) and ten corrosion test objects. The ten reinforcements in the test object will be accelerated by corrosion according to a predetermined time and the desired corrosion rate based on Faraday's law. Therefore, the accelerated corrosion reinforcement is used as reinforcement in the concrete to be cast. On 28 days old concrete, the flexural strength test was carried out using the Universal Testing Machine. The highest flexural strength test results on the test object E with a corrosion rate of 5% with an average of 1.905 MPa. From the research, it can be concluded that the increase in the percentage of corrosion in the reinforcement causes a decrease in the flexural strength value
| Dosen Pembimbing: | AHMAD ZAKI, IR., S.T., M.SC., PH.D. | NIDN1004118405 |
|---|---|
| Item Type: | Thesis (S1) |
| Uncontrolled Keywords: | CONCRETE, OIL PALM SHELL, MASK FIBER, CORROSION, FLEXURAL STRENGTH |
| Divisions: | Fakultas Teknik > S1 Teknik Sipil |
| Depositing User: | M. Erdiansyah |
| Date Deposited: | 25 May 2022 03:06 |
| Last Modified: | 25 May 2022 03:06 |
| URI: | https://etd.umy.ac.id/id/eprint/31297 |
Actions (login required)
![]() |
View Item |
