ODE ABDUL HARIS (2022) ANALISIS KONDISI INTERNAL TRANSFORMATOR IBT 150KV/70KV BERBASIS SHUTDOWN TESTING (STUDI KASUS : GARDU INDUK 150KV SKYLIE, JAYAPURA). S1 thesis, Universitas Muhammadiyah Yogyakarta.
|
Text (Halaman Judul)
Halaman Judul.pdf Download (1MB) |
|
|
Text (Lembar Pengesahan)
Lembar Pengesahan.pdf Restricted to Registered users only Download (593kB) |
|
|
Text (Abstrak)
Abstrak.pdf Restricted to Registered users only Download (372kB) |
|
|
Text (Bab I)
Bab I.pdf Download (463kB) |
|
|
Text (Bab II)
Bab II.pdf Restricted to Registered users only Download (1MB) |
|
|
Text (Bab III)
Bab III.pdf Restricted to Registered users only Download (879kB) |
|
|
Text (Bab IV)
Bab IV.pdf Restricted to Registered users only Download (762kB) |
|
|
Text (Bab V)
Bab V.pdf Restricted to Registered users only Download (356kB) |
|
|
Text (Daftar Pustaka)
Daftar Pustaka.pdf Restricted to Registered users only Download (231kB) |
|
|
Text (Naskah Publikasi)
Naskah Publikasi.pdf Restricted to Registered users only Download (1MB) |
|
|
Text (Full Text)
Full Text.pdf Restricted to Repository staff only Download (6MB) |
Abstract
PADA GARDU INDUK TRANSFORMATOR MERUPAKAN ASET PALING PENTING, TRANSFORMATOR PADA GARDU INDUK BERFUNGSI UNTUK MENURUNKAN TEGANGAN YANG DITERIMA DARI PEMBANGKIT AGAR TEGANGAN DAPAT SESUAI DENGAN KEBUTUHAN KONSUMEN. NAMUN SEIRING DENGAN PENGGUNAANNYA, TRANSFORMATOR DAYA MEMERLUKAN PEMELIHARAAN YANG BENAR SECARA RUTIN UNTUK MENJAGA AGAR TIDAK TERJADI KETIDAKNORMALAN YANG DAPAT MERUGIKAN BAIK PENYEDIA LAYANAN LISTRIK MAUPUN KONSUMEN. UJI TRANSFORMATOR DALAM KEADAAN PADAM DILAKUKAN PADA SAAT PEMELIHARAAN RUTIN MAUPUN SAAT INVESTIGASI KETIDAKNORMALAN (ASSESMENT). TUJUAN DARI PENGUJIAN INI ADALAH UNTUK MENGETAHUI KONDISI PERALATAN-PERALATAN PADA TRANSFORMATOR IBT 150KV/70KV DALAM KEADAAN BAIK ATAU TIDAK SESUAI DENGAN STANDAR YANG BERLAKU DI PERUSAHAAN. METODE YANG DITERAPKAN DALAM PENELITIAN INI BERUPA PENGUJIAN SECARA LANGSUNG PADA TRANSFORMATOR IBT 150KV/70KV DI GARDU INDUK SKYLINE JAYAPURA DENGAN DIDASARI JURNAL, TEXTBOOK, MANUAL BOOK SERTA SUMBER LAIN YANG DAPAT DI PERCAYA. DATA YANG DI AMBIL PADA PENELITIAN INI BERUPA HASIL PENGUJIAN TAHANAN ISOLASI, RASIO, RDC, DAN TAN ? YANG DILAKUKAN PADA DUA TITIK (TAN ? ISOLASI WINDING DAN TAN ? BUSHING). HASIL PENGUJIAN MENUNJUKAN PADA TRANSFORMATOR IBT 150KV/70KV NILAI RASIO MASIH DALAM KONDISI BAIK YAITU DIBAWAH 0,5% NAMUN TERDAPAT KENAIKAN YANG CUKUP MENONJOL PADA TEGANGAN SISI T YANG MENYEBABKAN NILAI DEVIASI SISI T 0,26%. HASIL PENGUJIAN RDC MENUNJUKAN KONDISI YANG MASIH BAIK YAITU DIBAWAH 1% NAMUN TERDAPAT KENAIKAN MENGALAMI KENAIKAN YANG SIGNIFIKAN PADA PRIMER R 0,07%, PRIMER S 0,06
| Dosen Pembimbing: | RAMADONI SYAHPUTRA, DR. IR., S.T., M.T. and SLAMET SURIPTO, IR., M.ENG | NIDN0510107403, NIDN0518116102 |
|---|---|
| Item Type: | Thesis (S1) |
| Uncontrolled Keywords: | INTERBUS TRANSFORMER, SHUTDOWN TESTING, RATIO, RDC, TAN ? |
| Divisions: | Fakultas Teknik > S1 Teknik Elektro |
| Depositing User: | Eko Kurnawan |
| Date Deposited: | 21 May 2022 06:33 |
| Last Modified: | 21 May 2022 06:33 |
| URI: | https://etd.umy.ac.id/id/eprint/31986 |