DESGENTIAS ROID HAZAZI (2019) PENGARUH PH SALIVA TERHADAP PELEPASAN ION NIKEL KAWAT ORTODONTIK NIKEL TITANIUM. S1 thesis, Universitas Muhammadiyah Yogyakarta.

[thumbnail of COVER] Text (COVER)
COVER

Download (109kB)
[thumbnail of HALAMAN JUDUL] Text (HALAMAN JUDUL)
HALAMAN JUDUL

Download (756kB)
[thumbnail of HALAMAN PENGESAHAN] Text (HALAMAN PENGESAHAN)
HALAMAN PENGESAHAN
Restricted to Registered users only

Download (493kB)
[thumbnail of ABSTRAK] Text (ABSTRAK)
ABSTRAK

Download (97kB)
[thumbnail of BAB I] Text (BAB I)
BAB I

Download (181kB)
[thumbnail of BAB II] Text (BAB II)
BAB II
Restricted to Registered users only

Download (208kB)
[thumbnail of BAB III] Text (BAB III)
BAB III
Restricted to Registered users only

Download (240kB)
[thumbnail of BAB IV] Text (BAB IV)
BAB IV
Restricted to Registered users only

Download (291kB)
[thumbnail of BAB V] Text (BAB V)
BAB V
Restricted to Registered users only

Download (93kB)
[thumbnail of DAFTAR PUSTAKA] Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA
Restricted to Registered users only

Download (262kB)
[thumbnail of LAMPIRAN] Text (LAMPIRAN)
LAMPIRAN
Restricted to Registered users only

Download (460kB)
[thumbnail of NASKAH PUBLIKASI] Text (NASKAH PUBLIKASI)
NASKAH PUBLIKASI
Restricted to Registered users only

Download (295kB)
Official URL: http://repository.umy.ac.id/handle/123456789/28527

Abstract

Background: : Orthodontic wire has several types such as beta titanium, stainless steel, and titanium nickel. Saliva has a normal pH condition, but several factors can affect the condition to be acid or basic. Objective: to find out whether or not the release of nickel-made orthodontic wire nickel ion is immersed in normal pH and acidic. Method: laboratory experimental method, with a cross sectional research design. The number of samples used in this study are 40 orthodontic wire samples made from nickel titanium which are divided into 10 groups. Then immersion using saliva pH 6.75 and pH 4.8 for 1 day, 7 days, 14 days, 21 days, and 28 days. The data obtained were analyzed using Independent T test Results: Results performed on day 1, day 7, day 14, day 21, and day 28 experienced ion release. Conclusion: titanium nickel orthodontic wires which are immersed undergo ion release. The longer the immersion takes, the more nickel ions are released.

Dosen Pembimbing: UNSPECIFIED | UNSPECIFIED
Item Type: Thesis (S1)
Uncontrolled Keywords: ORTHODONTIC WIRE, ION RELEASE, NICKEL, IMMERSION