RAMDHAN SYAH PUTRA (2020) ANALISIS PERBANDINGAN KONSUMSI ENERGI LISTRIK AC VRV DENGAN AC CHILLER UNTUK PEMILIHAN AC YANG EFISIEN. S1 thesis, Universitas Muhammadiyah Yogyakarta.
|
Text (COVER)
COVER Download (31kB) |
|
|
Text (HALAMAN JUDUL)
HALAMAN JUDUL Download (1MB) |
|
|
Text (HALAMAN PENGESAHAN)
HALAMAN PENGESAHAN Restricted to Registered users only Download (1MB) |
|
|
Text (ABSTRAK)
ABSTRAK Download (109kB) |
|
|
Text (BAB I)
BAB I Download (126kB) |
|
|
Text (BAB II)
BAB II Restricted to Registered users only Download (611kB) |
|
|
Text (BAB III)
BAB III Restricted to Registered users only Download (12kB) |
|
|
Text (BAB IV)
BAB IV Restricted to Registered users only Download (12kB) |
|
|
Text (BAB V)
BAB V Restricted to Registered users only Download (124kB) |
|
|
Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA Restricted to Registered users only Download (111kB) |
|
|
Text (DAFTAR PUSTAKA)
DAFTAR PUSTAKA Restricted to Registered users only Download (111kB) |
|
|
Text (LAMPIRAN)
LAMPIRAN Restricted to Registered users only Download (14MB) |
Abstract
In designing a building, technical planning such as mechanical and Electrical planning is needed, which includes air planning. The purposes of this research is to find out how much electricity consumption is used by the VRV system and the Chiller system, so we get also an estimate of the electricity costs that need to be incurred during the system use. To find out how much electricity consumption is expended by the system, it is necessary to know the capacity of the rooms cooling requirements along with the electrical power of the system, the data is obtained from the research site, product catalog, and supporting journals so that it can be simulated electrical energy consumption. The results of this study indicate the specifications and material or system components used, the simulation of the electrical energy consumption of the system, the electricity cost of the system, and the comparison of the electricity costs of the two systems namely the VRV system and the chiller system.
| Dosen Pembimbing: | UNSPECIFIED | UNSPECIFIED |
|---|---|
| Item Type: | Thesis (S1) |
| Uncontrolled Keywords: | VRV SYSTEM; CHILLER SYSTEM; COOLING LOAD CAPACITY; ELECTRIC ENERGY CONSUMPTION SIMULATION; ELECTRIC ENERGY CONSUMPTION COST |
| Divisions: | Fakultas Teknik > S1 Teknik Elektro |
| Depositing User: | Unnamed user with email Admin Perpustakaan 1 |
| Last Modified: | 09 Oct 2025 03:03 |
| URI: | https://etd.umy.ac.id/id/eprint/58036 |
Actions (login required)
![]() |
View Item |