KAJIAN ANALISIS EFISIENSI KESELURUHAN TURBIN AIR FRANCIS PADA TAHUN 2011 DI PLTA IR H DJUANDA PURWAKARTA

ADITYA FERDIANTO (2014) KAJIAN ANALISIS EFISIENSI KESELURUHAN TURBIN AIR FRANCIS PADA TAHUN 2011 DI PLTA IR H DJUANDA PURWAKARTA. S1 thesis, Universitas Muhammadiyah Yogyakarta.

[thumbnail of Abstract] Text (Abstract)
Abstract.pdf

Download (611kB)
[thumbnail of Bab I] Text (Bab I)
Bab I.pdf

Download (28kB)
[thumbnail of Bab II] Text (Bab II)
Bab II.pdf
Restricted to Registered users only

Download (411kB)
[thumbnail of Bab III] Text (Bab III)
Bab III.pdf
Restricted to Registered users only

Download (190kB)
[thumbnail of Bab IV] Text (Bab IV)
Bab IV.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of Bab V] Text (Bab V)
Bab V.pdf
Restricted to Registered users only

Download (15kB)

Abstract

BERDASARKAN HASIL PENELITIAN DIPEROLEH EFISIENSI KESELURUHAN SELAMA TAHUN 2011UNTUK BULAN JANUARI HANYA UNIT 1, UNIT 2 DAN 6 YANG MEMENUHI STANDAR. PADA BULAN FEBRUARI YANG MEMENUHI STANDAR HANYA 1, LALU PADA BULAM MARET UNIT 1, UNIT 3 DAN 4 YANGMEMENUHI STANDAR. UNTUK BULAN APRIL HANYA UNIT 1DAN 3 YANG MEMENUHI STANDAR. BULAN MEI HANYA 5 YANG DIBAWAH STANDAR DAN UNIT 6 MATI TOTAL.BULAN JUNI UNIT 3, UNIT 4, UNIT 5 YANG MEMENUHI STANDAR. PADA BULAN JULI HANYA UNIT 6 YANG EFESIENSI KURANG DARI DARI STANDAR. UNTUK BULAN AGUSTUS HANYA UNIT 5 DAN UNIT 6 YANG KURANG DARI STANDAR. BULAN SEPTEMBER HANYA UNTIT 2 YANG YANGMEMENUHI STANDAR. BULAN OKTOBER HANYA 1 YANG MEMENUHI STANDAR, LALU PADA BULANNOVEMBER KE 6 UNIT SELURUHNYA DIBAWAH STANDAR. PADA BULAN DESEMBER HANYA UNIT 2 YANG DIBAWAH STANDAR DAN UNIT 6 KONDISINYA MATI TOTAL. DARI PENELITIAN INI DISIMPULKAN BAHWA TURBIN UNIT 1, UNIT 3, UNIT 4, DAN UNIT 5 MASIH BISA DIGUNAKAN DENGAN NORMAL WALAUPUN TERDAPAT PENURUNAN EFISIENSI DI BULAN-BULAN TERTENTU, SEDANGKAN UNTUK TURBIN UNIT 2 DAN UNIT 6 PERLU SEGERA DILAKUKANNYA MAINTENANCE TERUTAMA DI UNIT 6 YANG SERING MENGALAMI KERUSAKAN SELAMA 2011 DAN PENYEBAB UTAMA MENURUNNYA EFISIENSI DAN PERFORMA TURBIN DISEBABKAN OLEH FAKTOR USIA KOMPONEN YANG MEMANG SUDAH WAKTUNYA UNTUK DIGANTI.

Item Type: Thesis (S1)
Uncontrolled Keywords: PLTA - IR H DHUANDA - TURBIN FRANCIS - TURBIN REAKSI - EFISIENSI KESELURUHAN
Divisions: Fakultas Teknik > Teknik Mesin S1
Depositing User: Unnamed user with email robi@umy.ac.id
Date Deposited: 20 Jun 2022 04:26
Last Modified: 20 Jun 2022 04:26
URI: https://etd.umy.ac.id/id/eprint/15729