Sheila Syafira Zen (2020) PERANCANGAN PENYIMPAN DAN PEMANAS ASIP BERBASIS MIKROKONTROLER ATMEGA328. S1 thesis, Universitas Muhammadiyah Yogyakarta.
![]() |
Text (Halaman Judul)
Halaman Judul.pdf Download (424kB) |
![]() |
Text (Lembar Pengesahan)
Lembar Pengesahan.pdf Restricted to Registered users only Download (403kB) |
![]() |
Text (Abstrak)
Abstrak.pdf Restricted to Registered users only Download (101kB) |
![]() |
Text (Bab I)
Bab I.pdf Download (105kB) |
![]() |
Text (Bab II)
Bab II.pdf Restricted to Registered users only Download (332kB) |
![]() |
Text (Bab III)
Bab III.pdf Restricted to Registered users only Download (371kB) |
![]() |
Text (Bab IV)
Bab IV.pdf Restricted to Registered users only Download (379kB) |
![]() |
Text (Bab V)
Bab V.pdf Restricted to Registered users only Download (38kB) |
![]() |
Text (Daftar Pustaka)
Daftar Pustaka.pdf Restricted to Registered users only Download (97kB) |
![]() |
Text (Lampiran)
Lampiran.pdf Restricted to Registered users only Download (91kB) |
![]() |
Text (Naskah Publikasi)
Naskah Publikasi.pdf Restricted to Registered users only Download (377kB) |
![]() |
Text (Full Text)
Full Text.pdf Restricted to Repository staff only Download (1MB) |
Abstract
Breast Milk (ASIP) is an important beverage for infants and has the benefit of nutrients
needed compared to formula milk, giving ASIP in infants can prevent some of the children's
illnesses because of the presence of antibodies in colostrum. Many factors can cause the failure of
exclusive breastfeeding to infants, including the culture of formula feeding because the mother has
to leave the child to work and giving formula milk because breast milk does not come out.
The making of ASIP Portable storage and heating devices with expired indicators aims to
store ASIP so that the nutritional content in ASIP remains stable and to warm ASIP before giving
it to the baby. This tool uses a peltier as a cooling source to maintain the durability of ASIP. LM35
sensor is used as a temperature reader in the box.
Temperature retrieval data is carried out 10 times. Based on the analysis results of
measurements on storage of ASIP with a temperature of 15oC has a deviation of -0.39 and an
error of -0.2. The results of the analysis of ASIP heating at 37oC have a deviation of -0.24 and an
error of -0.6
Dosen Pembimbing: | NUR HUDHA WIJAYA, S.T., M.ENG | NIDN0524018203 |
---|---|
Item Type: | Thesis (S1) |
Divisions: | Program Vokasi > D3 Teknologi Elektro-medis |
Depositing User: | Unnamed user with email robi@umy.ac.id |
Date Deposited: | 12 Oct 2021 03:57 |
Last Modified: | 03 Nov 2021 02:27 |
URI: | https://etd.umy.ac.id/id/eprint/2029 |
Actions (login required)
![]() |
View Item |