REKAYASA BABY INCUBATOR TRANSPORT DENGAN PARAMETER SUHU

M. TAKDIR OQBAH (2021) REKAYASA BABY INCUBATOR TRANSPORT DENGAN PARAMETER SUHU. S1 thesis, Universitas Muhammadiyah Yogyakarta.

[thumbnail of Halaman Judul] Text (Halaman Judul)
Halaman Judul.pdf

Download (1MB)
[thumbnail of Lembar Pengesahan] Text (Lembar Pengesahan)
Lembar Pengesahan.pdf
Restricted to Registered users only

Download (649kB)
[thumbnail of Abstrak] Text (Abstrak)
Abstrak.pdf
Restricted to Registered users only

Download (169kB)
[thumbnail of Bab I] Text (Bab I)
Bab I.pdf

Download (409kB)
[thumbnail of Bab II] Text (Bab II)
Bab II.pdf
Restricted to Registered users only

Download (391kB)
[thumbnail of Bab III] Text (Bab III)
Bab III.pdf
Restricted to Registered users only

Download (789kB)
[thumbnail of Bab IV] Text (Bab IV)
Bab IV.pdf
Restricted to Registered users only

Download (562kB)
[thumbnail of Bab V] Text (Bab V)
Bab V.pdf
Restricted to Registered users only

Download (168kB)
[thumbnail of Daftar Pustaka] Text (Daftar Pustaka)
Daftar Pustaka.pdf
Restricted to Registered users only

Download (285kB)
[thumbnail of Lampiran] Text (Lampiran)
Lampiran.pdf
Restricted to Registered users only

Download (973kB)
[thumbnail of Naskah Publikasi] Text (Naskah Publikasi)
Naskah Publikasi.pdf
Restricted to Registered users only

Download (661kB)
[thumbnail of Full Text] Text (Full Text)
Full Text.pdf
Restricted to Repository staff only

Download (3MB)

Abstract

To make it easier for health practitioners, especially nurses, to move babies from one room to another or to another hospital that has more complete equipment, a transport incubator is needed. In this study, modifications were made to the baby incubator transport with a room temperature setting of 32°C - 37°C with a seven segment display. Temperature monitoring uses a DS18B20 temperature sensor, which is then processed by a microcontroller to be displayed on the seven segment and uses an accumulator (AKI) as a voltage source for the baby incubator. From the test results, the error value at room temperature is 1% at the largest at a setting temperature of 35°C, while at a setting temperature at 37°C, the error value at the skin temperature is 1.2%. Based on the research, it was concluded that the tool can function properly.

Item Type: Thesis (S1)
Uncontrolled Keywords: AKUMULATOR(AKI),MICROKONTROLER,SENSOR DS18B20
Divisions: Program Vokasi > Teknologi Elektro-medis D3
Depositing User: M. Erdiansyah
Date Deposited: 18 May 2022 03:11
Last Modified: 18 May 2022 03:11
URI: https://etd.umy.ac.id/id/eprint/29088