GHALDA AULIA (2021) HYPOTHERMIA BLANKET BERBASIS ARDUINO. S1 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (572kB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (534kB)
Abstrak.pdf
Restricted to Registered users only
Download (123kB)
Bab I.pdf
Download (296kB)
Bab II.pdf
Restricted to Registered users only
Download (93kB)
Bab III.pdf
Restricted to Registered users only
Download (838kB)
Bab IV.pdf
Restricted to Registered users only
Download (523kB)
Bab V.pdf
Restricted to Registered users only
Download (184kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (122kB)
Lampiran.pdf
Restricted to Registered users only
Download (531kB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (681kB)
Full Text.pdf
Restricted to Repository staff only
Download (1MB)
Abstract
Hypothermia is defined as a clinical condition when the body temperature is below35°C. Hypothermia usually occurs in patients after surgery. The decrease in body temperature caused by low room temperature during and after surgery is the main factor that causes a sharp drop in the body temperature of hypothermic patients can have a negative impact on the patient. With an incident like this, the author decided to make a tool with the title "Hypothermia Blanket Based on Arduino" to solve problems in hypothermic patients quickly and precisely. The design of this tool uses Arduino uno as a processor and a DS18B20 sensor for temperature readings. Wet heater as a water heater, water pump as a driver of the water cycle from the tool to the blanket and vice versa. The temperature setting and mode will be displayed on the LCD screen. This tool will use 2 modes, namely manual mode, and automatic mode. And for testing the tool will use a digital thermometer to read the temperature. The temperature range used to set the tool is 34°C - 38°C. The highest error percentage value in the automatic mode setting is at a temperature setting of 34°C, 1.38% for tool error and 0.79% for thermometer error. And the highest error percentage value in manual mode setting is at 36°C temperature setting which is 1.33% for tool error and 1.18% for thermometer error. The percentage value of the average error is still within the tolerance value limit, which is ± 5%.
Item Type: | Thesis (S1) |
---|---|
Uncontrolled Keywords: | KATA KUNCI: HEATER BASAH, HIPOTERMIA, POMPA AIR, SENSOR SUHU DS18B20 |