KAMILA RAHMA TSALISA (2022) REKAYASA ALAT TERAPI ALZHEIMER DENGAN MENGGUNAKAN METODE FOTOBIOMODULASI. D3 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (395kB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (417kB)
Abstrak.pdf
Restricted to Registered users only
Download (141kB)
Bab I.pdf
Download (272kB)
Bab II.pdf
Restricted to Registered users only
Download (803kB)
Bab III.pdf
Restricted to Registered users only
Download (1MB)
Bab IV.pdf
Restricted to Registered users only
Download (488kB)
Bab V.pdf
Restricted to Registered users only
Download (143kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (165kB)
Lampiran.pdf
Restricted to Registered users only
Download (545kB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (896kB)
Full Text.pdf
Restricted to Repository staff only
Download (3MB)
Abstract
Brain photobiomodulation therapy using near infrared light (NIR) is a therapy for a variety of neurological and psychological conditions, especially for dementia and Alzheimer. The aim of this research is to design a brain photobiomodulation therapy device to relieve the symptoms of Alzheimer disease. This therapy device used NI) light emitted by a laser diode with a wavelength of 600 - 1100 nm. The recommended therapeutic dose is 1-20 J. The author makes a timer setting 20 minutes with total energy of 15.906 J. The measurement of the wavelength on the LED obtained an average result of 635.1875 nm with a measurement uncertainty of ±2.74 and the wavelength measurement on the laser diode is obtained results >780 nm with a measurement uncertainty of ±0.50. The voltage measurement was carried out 6 times using a Handheld Oscilloscope measuring instrument. The average measured on the LED is 3.351 Volts with a measurement uncertainty of ±0.00082. The average measured on the laser diode is 1,550 Volts with a measurement uncertainty of ±0.011. Current measurements were performed 6 times using a Handheld Oscilloscope. The average measured on the LED is 3.22 mA with a measurement uncertainty of ±0.01. The average measured on the laser diode is 1.59 mA with a measurement uncertainty of ±0.0004. From the test results it can be stated that the device is in good condition and can work according to its function.
Item Type: | Thesis (D3) |
---|---|
Uncontrolled Keywords: | ALZHEIMER, FOTOBIOMODULASI, NIR |
Divisions: | Program Vokasi > Teknologi Elektro-medis D3 |
Depositing User: | M. Erdiansyah |
Date Deposited: | 17 May 2022 06:52 |
Last Modified: | 17 May 2022 06:52 |
URI: | https://etd.umy.ac.id/id/eprint/29184 |