HYPERTHERMIA BLANKET BERBASIS ARDUINO

MEDIONI TYAS ANGGARI (2022) HYPERTHERMIA BLANKET BERBASIS ARDUINO. D3 thesis, Universitas Muhammadiyah Yogyakarta.

[thumbnail of Halaman Judul] Text (Halaman Judul)
Halaman Judul.pdf

Download (325kB)
[thumbnail of Lembar Pengesahan] Text (Lembar Pengesahan)
Lembar Pengesahan.pdf
Restricted to Registered users only

Download (235kB)
[thumbnail of Abstrak] Text (Abstrak)
Abstrak.pdf
Restricted to Registered users only

Download (41kB)
[thumbnail of Bab I] Text (Bab I)
Bab I.pdf

Download (92kB)
[thumbnail of Bab II] Text (Bab II)
Bab II.pdf
Restricted to Registered users only

Download (343kB)
[thumbnail of Bab III] Text (Bab III)
Bab III.pdf
Restricted to Registered users only

Download (590kB)
[thumbnail of Bab IV] Text (Bab IV)
Bab IV.pdf
Restricted to Registered users only

Download (358kB)
[thumbnail of Bab V] Text (Bab V)
Bab V.pdf
Restricted to Registered users only

Download (82kB)
[thumbnail of Daftar Pustaka] Text (Daftar Pustaka)
Daftar Pustaka.pdf
Restricted to Registered users only

Download (87kB)
[thumbnail of Lampiran] Text (Lampiran)
Lampiran.pdf
Restricted to Registered users only

Download (266kB)
[thumbnail of Naskah Publikasi] Text (Naskah Publikasi)
Naskah Publikasi.pdf
Restricted to Registered users only

Download (733kB)
[thumbnail of Full Text] Text (Full Text)
Full Text.pdf
Restricted to Repository staff only

Download (1MB)

Abstract

Blanketroll with arduino-based hyperthermia parameters is a tool that can stabilize or restore the body temperature that originally experienced hyperthermia (body temperature rose drastically from normal) to normal body temperature. This tool works by utilizing the flow of water pumped from the tool to the blanket by using a DC pump and then the blanket is placed on patients who have hyperthermia. This tool is designed using arduino uno as a processor and temperature sensor DS18B20 as a temperature detector in blankets and tools. To set the temperature and mode on blanketroll can be set by using a TFT LCD Nextion. The function test result in automatic mode of 16 °C temperature was obtained an error of 2.5% on the tool and an error on the thermometer of 1.4%. While in manual mode the temperature of 16 ° C obtained an error of 1.5% in the tool and an error on the thermometer of 1.6%.