ANALISIS PENGARUH TINGKAT KOROSI TULANGAN TERHADAP KAPASITAS KOLOM GEDUNG 8 LANTAI

RESTU KURNIAWAN (2022) ANALISIS PENGARUH TINGKAT KOROSI TULANGAN TERHADAP KAPASITAS KOLOM GEDUNG 8 LANTAI. S1 thesis, Universitas Muhammadiyah Yogyakarta.

[thumbnail of Halaman Judul] Text (Halaman Judul)
Halaman Judul.pdf

Download (1MB)
[thumbnail of Lembar Pengesahan] Text (Lembar Pengesahan)
Lembar Pengesahan.pdf
Restricted to Registered users only

Download (225kB)
[thumbnail of Abstrak] Text (Abstrak)
Abstrak.pdf
Restricted to Registered users only

Download (844kB)
[thumbnail of Bab I] Text (Bab I)
Bab I.pdf

Download (608kB)
[thumbnail of Bab II] Text (Bab II)
Bab II.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of Bab III] Text (Bab III)
Bab III.pdf
Restricted to Registered users only

Download (826kB)
[thumbnail of Bab IV] Text (Bab IV)
Bab IV.pdf
Restricted to Registered users only

Download (3MB)
[thumbnail of Bab V] Text (Bab V)
Bab V.pdf
Restricted to Registered users only

Download (566kB)
[thumbnail of Daftar Pustaka] Text (Daftar Pustaka)
Daftar Pustaka.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of Lampiran] Text (Lampiran)
Lampiran.pdf
Restricted to Registered users only

Download (10MB)
[thumbnail of Naskah Publikasi] Text (Naskah Publikasi)
Naskah Publikasi.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of Full Text] Text (Full Text)
Full Text.pdf
Restricted to Repository staff only

Download (23MB)

Abstract

KOROSI ADALAH SALAH SATU KERUSAKAN YANG TERJADI PADA STRUKTUR BETON BERTULANG. KOROSI ADALAH REAKSI ATOM FE DALAM TULANGAN MENJADI ION FE2+ ATAU FE3+. MEKANISME KOROSI YANG DISEBABKAN OLEH ION KLORIDA DAN KARBONASI. KOROSI YANG DIGUNAKAN DI PENGUJIAN INI MENGGUNAKAN KOROSI SERAGAM YANG DISIMULASIKAN DENGAN PENGURANGAN PENAMPANG DARI TULANGAN UNTUK MENGGAMBARKAN TINGKAT KOROSI STRUKTUR KOLOM YANG MENGALAMI KOROSI AKAN MEMPENGARUHI HASIL DIAGRAM INTERAKSI. KERUSAKAN KOROSI AKAN MENYEBABKAN KINERJA BANGUNAN BETON MENURUN, DAN JIKA KERUSAKAN BERLANJUT, MAKAN BANGUNAN BETON SUDAH TIDAK LAYAK PAKAI. CARA MENGATASI KOROSI DENGAN INHIBITOR KOROSI YAITU MENAMBAHKAN ELEMEN KIMIA KE LINGKUNGAN BAJA UNTUK MENGURANGI LAJU KOROSI. PENGUJIAN INI MENGGUNAKAN 6 BENDA UJI, 2 STUDI KASUS, DAN 4 PENAMBAHAN BEBAN. DESAIN STRUKTUR BETON MENGGUNAKAN PROGRAM BANTUAN SEPERTI SAP2000 UNTUK MENGANALISIS GAYA YANG MEMBEBANI STRUKTUR KEMUDIAN DIINTEGRASIKAN DENGAN PROGRAM SPCOLUMN UNTUK MENGETAHUI TULANGAN YANG MENGALAMI KOROSI MAMPU MENAHAN BEBAN DARI STRUKTUR BANGUNAN. DARI HASIL ANALSIS SPCOLUMN DIDAPATKAN KOLOM C1, C2, DAN C3 MAMPU MENAHAN BEBAN STRUKTUR HINGGA TINGKAT KOROSI 45%, SEDANGKAN C4-1, C4-2, DAN C5 MAMPU SAMPAI TINGKAT KOROSI 45%. NILAI KUAT LENTUR NOMINAL DAN KAPASITAS MOMEN MENGALAMI PENURUNAN HINGGA 36% PADA KOLOM C4-2 DENGAN PEMBEBANAN 0

Item Type: Thesis (S1)
Uncontrolled Keywords: KATA KUNCI: STRUKTUR BETON BERTULANG, KOROSI, DIAGRAM INTERAKSI, SPCOLUMN
Divisions: Fakultas Teknik > Teknik Sipil S1
Depositing User: Eko Kurnawan
Date Deposited: 19 May 2022 02:01
Last Modified: 19 May 2022 02:01
URI: https://etd.umy.ac.id/id/eprint/29824

Actions (login required)

View Item
View Item