ALFIKAR R TABANAL (2022) ANALISIS KEANDALAN SISTEM DISTRIBUSI PADA RAYON SLEMAN DI GARDU INDUK KENTUNGAN TAHUN 2020. S2 thesis, Universitas Muhammadiyah Yogyakarta.
![]() |
Text (Halaman Judul)
Halaman Judul.pdf Download (673kB) |
![]() |
Text (Lembar Pengesahan)
Lembar Pengesahan.pdf Restricted to Registered users only Download (665kB) |
![]() |
Text (Abstrak)
Abstrak.pdf Restricted to Registered users only Download (207kB) |
![]() |
Text (Bab I)
Bab I.pdf Download (336kB) |
![]() |
Text (Bab II)
Bab II.pdf Restricted to Registered users only Download (991kB) |
![]() |
Text (Bab III)
Bab III.pdf Restricted to Registered users only Download (253kB) |
![]() |
Text (Bab IV)
Bab IV.pdf Restricted to Registered users only Download (823kB) |
![]() |
Text (Bab V)
Bab V.pdf Restricted to Registered users only Download (209kB) |
![]() |
Text (Daftar Pustaka)
Daftar Pustaka.pdf Restricted to Registered users only Download (426kB) |
![]() |
Text (Lampiran)
Lampiran.pdf Restricted to Registered users only Download (564kB) |
![]() |
Text (Naskah Publikasi)
Naskah Publikasi.pdf Restricted to Registered users only Download (761kB) |
![]() |
Text (Full Text)
Full Text.pdf Restricted to Repository staff only Download (2MB) |
Abstract
KEANDALAN ADALAH PROBABILITAS BAHWA PERANGKAT ATAU SISTEM AKAN BERFUNGSI DENGAN BAIK DALAM JUMLAH WAKTU TERTENTU DI BAWAH KONDISI OPERASI TERTENTU. INDEKS KEANDALAN MERUPAKAN SEBUAH TOLAK UKUR UNTUK MENGETAHUI PERFORMA KEANDALAN SUATU SYSTEM DISTRIBUSI. INDEKS KEANDALAN YANG PALING SERING DIGUNAKAN YAITU SAIFI (SYSTEM AVERAGE INTERRUPTION FREQUENCY INDEX), SAIDI (SYSTEM AVERAGE INTERRUPTION DURATION INDEX), DAN CAIDI (CUSTOMER AVERAGE INTERRUPTION DURATION INDEX). HASIL TINJAUAN DENGAN MENGACU PADA STANDAR SPLN (STANDAR PERUSAHAAN LISTRIK NEGARA) 68-2 : 1986. NILAI TOTAL SAIFI, SAIDI DAN CAIDI SELURUH PENYULANG DAPAT DIKATAKAN HANDAL KARENA TIDAK MELEWATI BATASAN. SEDANGKAN JIKA MENGACU PADA IEEE STD. 1366-2003 NILAI TOTAL SAIFI, SAIDI DAN CAIDI DAPAT DIKATAKAN KURANG HANDAL KARENA MELEWATI BATASAN STANDAR TERSEBUT. BERDASARKAN HASIL PERHITUNGAN NILAI INDEKS KEANDALAN UNTUK TIAP PENYULANG PADA GARDU INDUK KENTUNGAN YANG MELAYANI RAYON SLEMAN. HAMPIR SELURUH PENYULANG DAPAT DIKATAKAN HANDAL. HANYA TERDAPAT 1 (SATU) PENYUULANG YANG NILAI NYA MELEWATI BATASAN DARI STANDAR IEEE STD. 1366-2003 YAITU KTN-01.
Dosen Pembimbing: | SLAMET SURIPTO, IR., M.ENG and KUNNU PURWANTO, S.T., M.ENG. | NIDN0518116102, NIDN0519098302 |
---|---|
Item Type: | Thesis (S2) |
Uncontrolled Keywords: | RELIABILITY (RELIABILITY), STANDARD SPLN 68-2: 1986, IEEE STD. 1366- 2003, SAIFI, SAIDI, CAIDI. |
Divisions: | Fakultas Teknik > S1 Teknik Elektro |