MUHAMMAD ABDURROHMAN (2022) ANALISIS TRAFO CT DAYA NON-CT PADA INVERTER. S1 thesis, Universitas Muhammadiyah Yogyakarta.
![]() |
Text (Halaman Judul)
Halaman Judul.pdf Download (809kB) |
![]() |
Text (Lembar Pengesahan)
Lembar Pengesahan.pdf Restricted to Registered users only Download (865kB) |
![]() |
Text (Abstrak)
Abstrak.pdf Restricted to Registered users only Download (34kB) |
![]() |
Text (Bab I)
Bab I.pdf Download (132kB) |
![]() |
Text (Bab II)
Bab II.pdf Restricted to Registered users only Download (420kB) |
![]() |
Text (Bab III)
Bab III.pdf Restricted to Registered users only Download (1MB) |
![]() |
Text (Bab IV)
Bab IV.pdf Restricted to Registered users only Download (1MB) |
![]() |
Text (Bab V)
Bab V.pdf Restricted to Registered users only Download (36kB) |
![]() |
Text (Daftar Pustaka)
Daftar Pustaka.pdf Restricted to Registered users only Download (102kB) |
![]() |
Text (Lampiran)
Lampiran.pdf Restricted to Registered users only Download (76kB) |
![]() |
Text (Naskah Publikasi)
Naskah Publikasi.pdf Restricted to Registered users only Download (742kB) |
![]() |
Text (Full Text)
Full Text.pdf Restricted to Repository staff only Download (4MB) |
Abstract
DIERA MODERN SAAT INI SUMBER DAYA LISTRIK BERPERAN PENTING DALAM AKTIFITAS SEHARI-HARI. KENDALA YANG SERING TERJADI KETIKA PEMADAMAN LISTRIK DARI PT.PLN SUMBER DAYA LISTRIK PADA RUMAH TANGGA AKAN MATI TOTAL. SEIRING BERKEMBANGNYA TEKNOLOGI DUNIA ELEKTRONIKA ADANYA SEBUAH INVERTER DAPAT DIGUNAKAN SEBAGAI CADANGAN LISTRIK SAAT TERJADINYA PEMADAMAN DARI PT.PLN. INVERTER ADALAH SEBUAH PERANGKAT ELEKTRONIKA YANG BERFUNGSI SEBAGAI PENGUBAH TEGANGAN (DIRECT CURENTT) DC, YANG MEMANFAATKAN SUMBER MATAHARI,AKI/BATERAI YAG AKAN DIUBAH MENJADI (ALTERNATING CURRENT) AC YANG DAPAT DIGUNAKAN PADA BEBAN RESISTIF, INDUKTIF, KAPASITIF ATAU TEGANGAN (ALTERNATING CURRENT) AC LAINNYA. PENELITIAN INI BERTUJUAN MEMBUAT DUA BUAH RANGKAIAN INVERTER MENGGUNAKAN TRAFO CT DAN NON-CT DENGAN KONTROLLER YANG SAMA DAN DRIVER YANG BERBEDA, DAN AKAN DILAKUKAN ANALISIS TERHADAP BEBAN PADA KEDUA TRAFO YANG DIGUNAKAN. SUMBER TEGANGAN INPUT YANG DIGUNAKAN SEBESAR 12VDC KEMUDIAN AKAN DIUBAH MENJADI TEGANGAN OUTPUT 220 VAC. PENGUJIAN DILAKUKAN MENGGUNAKAN OSILOSCOP UNTUK MENGAMATI BENTUK GELOMBANG DAN FREKUENSI YANG DIHASILKAN PADA KEDUA INVERTER, KEMUDIAN MENGAMATI TEGANGAN OUTPUT DAN FEEDBACK MENGGUNAKAN MULTIMETER PADA MASING-MASING INVERTER. DARI HASIL PENGUJIAN MENUNJUKAN BAHWA GELOMBANG INVERTER TRAFO CT MAMPU MENGAHASILKAN GELOMBANG SINUS MURNI YANG LEBIH BAIK DIBANDINGAKAN INVERTER TRAFO NON-CT DENGAN FREKUENSI SEBESAR 50 HZ DENGAN TEGANGAN OUTPUT 220 VAC. INVERTER TRAFO NON-CT MEMILIKI NOISE YANG LEBIH BESAR DIBANDINGKAN INVERTER CT, PADA BEBAN YANG SAMA. HASIL PENGUJIAN INVERTER NON-CT MENGGUNAKAN BEBAN DAYA 100 WATT TERJADI DROP TEGANGAN YANG TIDAK MEMUNGKINKAN.
Dosen Pembimbing: | KUNNU PURWANTO, S.T., M.ENG. and RAHMAT ADIPRASETYA AL HASIBI, DR. IR., S.T., M.ENG., IPM. | NIDN0519098302, NIDN0011117502 |
---|---|
Item Type: | Thesis (S1) |
Uncontrolled Keywords: | INVERTER, CT TRANSFORMER, NON-CT TRANSFORMER, FREQUENCY. |
Divisions: | Fakultas Teknik > S1 Teknik Elektro |