MUHAMMAD ABDURROHMAN (2022) ANALISIS TRAFO CT DAYA NON-CT PADA INVERTER. S1 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (809kB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (865kB)
Abstrak.pdf
Restricted to Registered users only
Download (34kB)
Bab I.pdf
Download (132kB)
Bab II.pdf
Restricted to Registered users only
Download (420kB)
Bab III.pdf
Restricted to Registered users only
Download (1MB)
Bab IV.pdf
Restricted to Registered users only
Download (1MB)
Bab V.pdf
Restricted to Registered users only
Download (36kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (102kB)
Lampiran.pdf
Restricted to Registered users only
Download (76kB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (742kB)
Full Text.pdf
Restricted to Repository staff only
Download (4MB)
Abstract
DIERA MODERN SAAT INI SUMBER DAYA LISTRIK BERPERAN PENTING DALAM AKTIFITAS SEHARI-HARI. KENDALA YANG SERING TERJADI KETIKA PEMADAMAN LISTRIK DARI PT.PLN SUMBER DAYA LISTRIK PADA RUMAH TANGGA AKAN MATI TOTAL. SEIRING BERKEMBANGNYA TEKNOLOGI DUNIA ELEKTRONIKA ADANYA SEBUAH INVERTER DAPAT DIGUNAKAN SEBAGAI CADANGAN LISTRIK SAAT TERJADINYA PEMADAMAN DARI PT.PLN. INVERTER ADALAH SEBUAH PERANGKAT ELEKTRONIKA YANG BERFUNGSI SEBAGAI PENGUBAH TEGANGAN (DIRECT CURENTT) DC, YANG MEMANFAATKAN SUMBER MATAHARI,AKI/BATERAI YAG AKAN DIUBAH MENJADI (ALTERNATING CURRENT) AC YANG DAPAT DIGUNAKAN PADA BEBAN RESISTIF, INDUKTIF, KAPASITIF ATAU TEGANGAN (ALTERNATING CURRENT) AC LAINNYA. PENELITIAN INI BERTUJUAN MEMBUAT DUA BUAH RANGKAIAN INVERTER MENGGUNAKAN TRAFO CT DAN NON-CT DENGAN KONTROLLER YANG SAMA DAN DRIVER YANG BERBEDA, DAN AKAN DILAKUKAN ANALISIS TERHADAP BEBAN PADA KEDUA TRAFO YANG DIGUNAKAN. SUMBER TEGANGAN INPUT YANG DIGUNAKAN SEBESAR 12VDC KEMUDIAN AKAN DIUBAH MENJADI TEGANGAN OUTPUT 220 VAC. PENGUJIAN DILAKUKAN MENGGUNAKAN OSILOSCOP UNTUK MENGAMATI BENTUK GELOMBANG DAN FREKUENSI YANG DIHASILKAN PADA KEDUA INVERTER, KEMUDIAN MENGAMATI TEGANGAN OUTPUT DAN FEEDBACK MENGGUNAKAN MULTIMETER PADA MASING-MASING INVERTER. DARI HASIL PENGUJIAN MENUNJUKAN BAHWA GELOMBANG INVERTER TRAFO CT MAMPU MENGAHASILKAN GELOMBANG SINUS MURNI YANG LEBIH BAIK DIBANDINGAKAN INVERTER TRAFO NON-CT DENGAN FREKUENSI SEBESAR 50 HZ DENGAN TEGANGAN OUTPUT 220 VAC. INVERTER TRAFO NON-CT MEMILIKI NOISE YANG LEBIH BESAR DIBANDINGKAN INVERTER CT, PADA BEBAN YANG SAMA. HASIL PENGUJIAN INVERTER NON-CT MENGGUNAKAN BEBAN DAYA 100 WATT TERJADI DROP TEGANGAN YANG TIDAK MEMUNGKINKAN.