FIRDA SHAFIRA PANE (2022) KALIBRATOR TENSIMETER DIGITAL. D3 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (948kB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (1MB)
Abstrak.pdf
Restricted to Registered users only
Download (153kB)
Bab I.pdf
Download (274kB)
Bab II.pdf
Restricted to Registered users only
Download (380kB)
Bab III.pdf
Restricted to Registered users only
Download (553kB)
Bab IV.pdf
Restricted to Registered users only
Download (494kB)
Bab V.pdf
Restricted to Registered users only
Download (155kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (269kB)
Lampiran.pdf
Restricted to Registered users only
Download (487kB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (423kB)
Full Text.pdf
Restricted to Repository staff only
Download (1MB)
Abstract
KEMENKES MELARANG PEMAKAIAN TENSIMETER ANALOG YANG MENGGUNAKAN MERKURI DIKARENAKAN BERBAHAYA JIKA SAMPAI TERKENA DAN TERHIRUP OLEH PASIEN, OLEH KARENA ITU RUMAH SAKIT MULAI BANYAK MENGGUNAKAN TENSIMETER DIGITAL. SEMENTARA ITU, PENGUKURAN TEKANAN DARAH PADA ALAT TENSIMETER DIGITAL HARUS DILAKUKAN DENGAN TEPAT. BERKAITAN DENGAN HAL TERSEBUT PERLU DILAKUKAN KALIBRASI TENSIMETER AGAR TIDAK TERJADI KESALAHAN DALAM DIAGNOSA. PADA PENELITIAN INI PENULIS AKAN MEMBUAT KALIBRATOR TENSIMETER DIGITAL DENGAN MEMANFAATKAN SENSOR MPX5100GP YANG TERHUBUNG PADA MINIMUM SISTEM ATMEGA 328. PADA SAAT ALAT DINYALAKAN, MAKA ALAT AKAN MELAKUKAN INISIALISASI PADA LIQUID CRYSTAL DISPLAY (LCD), KEMUDIAN PILIH PARAMETER PENGUKURAN MODE YANG DIINGINKAN. SETELAH ITU, ALAT TENSIMETER DIGITAL AKAN MEMBERIKAN TEKANAN YANG KEMUDIAN AKAN DIBERI OSILASI OLEH ALAT KALIBRATOR INI. JIKA HASIL PADA TAMPILAN LCD TENSIMETER DIGITAL SESUAI DENGAN MODE YANG DITENTUKAN, MAKA ALAT TENSIMETER DIGITAL DINYATAKAN LAIK PAKAI. PENGUJIAN KALIBRATOR TENSIMETER DIGITAL INI DIBANDINGKAN DENGAN FLUKE PROSIM 8 VITAL SIGN SIMULATOR. BERDASARKAN HASIL PENGUJIAN YANG DILAKUKAN, ALAT BEKERJA SESUAI YANG DIRENCANAKAN. HASIL PENGUJIAN PADA NILAI SISTOL, ERROR YANG TERTINGGI SEBESAR 1,7% PADA NEONATAL DAN 0,6% PADA HIPERTENSI UNTUK NILAI ERROR SISTOL YANG TERENDAH. PADA NILAI DIASTOL, ERROR TERTINGGI YANG DIDAPATKAN SEBESAR 4,3% PADA NEONATAL DAN 2,15% PADA ADULT UNTUK YANG TERENDAH. KATA KUNCI : TENSIMETER DIGITAL, KALIBRATOR TENSIMETER DIGITAL, TEKANAN DARAH
Item Type: | Thesis (D3) |
---|---|
Uncontrolled Keywords: | DIGITAL SPHYGMOMANOMETER, DIGITAL SPHYGMOMANOMETER CALIBRATOR, BLOOD PRESSURE |
Divisions: | Program Vokasi > Teknologi Elektro-medis D3 |
Depositing User: | Eko Kurnawan |
Date Deposited: | 26 Apr 2022 02:19 |
Last Modified: | 26 Apr 2022 02:19 |
URI: | https://etd.umy.ac.id/id/eprint/30528 |