CO2 INSUFFLATOR DENGAN PARAMETER FLOW DAN TEKANAN

DENI HIDAYAT (2022) CO2 INSUFFLATOR DENGAN PARAMETER FLOW DAN TEKANAN. D3 thesis, Universitas Muhammadiyah Yogyakarta.

[thumbnail of Halaman Judul] Text (Halaman Judul)
Halaman Judul.pdf

Download (569kB)
[thumbnail of Lembar Pengesahan] Text (Lembar Pengesahan)
Lembar Pengesahan.pdf
Restricted to Registered users only

Download (564kB)
[thumbnail of Abstrak] Text (Abstrak)
Abstrak.pdf
Restricted to Registered users only

Download (67kB)
[thumbnail of Bab I] Text (Bab I)
Bab I.pdf

Download (74kB)
[thumbnail of Bab II] Text (Bab II)
Bab II.pdf
Restricted to Registered users only

Download (249kB)
[thumbnail of Bab III] Text (Bab III)
Bab III.pdf
Restricted to Registered users only

Download (584kB)
[thumbnail of Bab IV] Text (Bab IV)
Bab IV.pdf
Restricted to Registered users only

Download (416kB)
[thumbnail of Bab V] Text (Bab V)
Bab V.pdf
Restricted to Registered users only

Download (65kB)
[thumbnail of Daftar Pustaka] Text (Daftar Pustaka)
Daftar Pustaka.pdf
Restricted to Registered users only

Download (131kB)
[thumbnail of Lampiran] Text (Lampiran)
Lampiran.pdf
Restricted to Registered users only

Download (327kB)
[thumbnail of Naskah Publikasi] Text (Naskah Publikasi)
Naskah Publikasi.pdf
Restricted to Registered users only

Download (350kB)
[thumbnail of Full Text] Text (Full Text)
Full Text.pdf
Restricted to Repository staff only

Download (1MB)

Abstract

LAPAROSKOPI ADALAH METODE BEDAH INVASIVE YANG MEMINIMALISIR PEMBEDAHAN PADA DINDING PERUT, OPERASI INI DILAKUKAN DALAM DIAGNOSIS INTRA-ABDOMEN MELALUI INSPEKSI LANGSUNG ORGAN-ORGAN INTRA-ABDOMEN. BEDAH LAPAROSKOPI MEMERLUKAN PROSEDUR PNEUMOPERITONEUM YAITU PROSEDUR MENGEMBUNGKAN ABDOMEN MENGGUNAKAN GAS CO2 MELALUI JARUM VERRES ATAU TUOHY. ALAT YANG DIGUNAKAN DALAM PROSEDUR PNEUMOPERITONEUM DIKENAL DENGAN CO2 INSUFFLATOR. CO2 INSUFFLATOR ADALAH ALAT INSUFLASI YANG DIGUNAKAN DALAM PEMERIKSAAN DAN OPERASI LAPAROSKOPI ATAU ENDOSKOPI. DALAM PENELITIAN INI PENULIS MEMBUAT ALAT CO2 INSUFFLATOR DENGAN PARAMETER FLOW DAN TEKANAN. ADAPUN KOMPONEN YANG DIGUNAKAN DALAM PEMBUATAN ALAT PENELITIAN INI ADALAH ARDUINO MEGA2560 SEBAGAI PENGATUR SISTEM KERJA ALAT, MPX5100 SEBAGAI SENSOT PEMBACA NILAI TEKANAN, YF-S401 SEBAGAI SENSOR PEMBACA NILAI FLOW DAN VOLUME, TM1637 DAN SEVEN-SEGMENT SEBAGAI RANGKAIAN DISPLAY, DAN VALVE SEBAGAI PENGATUR MASUK DAN KELUAR GAS. BERDASARKAN HASIL PADA PENGUJIAN PARAMETER TEKANAN NILAI ERROR TERTINGGI SEBESAR 0,6% PADA SETTING 25 MMHG DAN NILAI ERROR TERENDAH SEBESAR 0,1% PADA TEKANAN 20 MMHG DAN 21 MMHG. PADA PARAMETER FLOW NILAI ERROR TERTINGGI SEBESAR 5,9% PADA SETTING FLOW 0,1 LPM DAN NILAI ERROR TERENDAH SEBESAR 1,4% PADA SETTING FLOW 1,0 LPM.

Item Type: Thesis (D3)
Uncontrolled Keywords: KATA KUNCI : LAPAROSKOPI, CO2 INSUFFLATOR, TEKANAN DAN FLOW.
Divisions: Program Vokasi > Teknologi Elektro-medis D3