KHIDIR ROMADHONSYAH (2022) ANALISIS KINERJA AUTOMATIC VOLTAGE REGULATOR (AVR) PADA PLTA TES. S1 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (265kB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (1MB)
Abstrak.pdf
Restricted to Registered users only
Download (8kB)
Bab I.pdf
Download (16kB)
Bab II.pdf
Restricted to Registered users only
Download (492kB)
Bab III.pdf
Restricted to Registered users only
Download (133kB)
Bab IV.pdf
Restricted to Registered users only
Download (378kB)
Bab V.pdf
Restricted to Registered users only
Download (7kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (71kB)
Lampiran.pdf
Restricted to Registered users only
Download (312kB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (443kB)
Full Text.pdf
Restricted to Repository staff only
Download (2MB)
Abstract
KESTABILAN TEGANGAN KELUARAN GENERATOR SANGAT MEMPENGARUHI SISTEM PEMBANGKITAN LISTRIK. AUTOMATIC VOLTAGE REGULATOR (AVR) MERUPAKAN ALAT PENSTABIL TEGANGAN TERMINAL GENERATOR. AVR BEKERJA DENGAN CARA MENGATUR EKSITASI AGAR FLUKS MEDAN DAN TEGANGAN TERMINAL NYA TETAP STABIL. PERAN AVR PADA PLTA TES YANG MERUPAKAN SALAH SATU PLTA TERTUA DI INDONESIA ADALAH SANGAT VITAL DAN MENDUKUNG KEBERLANGSUNGAN OPERASI PEMBANGKIT DI AREA BENGKULU. PENELITIAN INI BERTUJUAN UNTUK MENGANALISIS KINERJA AVR PADA GENERATOR DI PLTA TES. METODE YANG DI GUNAKAN YAITU DENGAN MENGUKUR PARAMETER SISTEM EKSITASI SAMPAI TEGANGAN KELUARAN GENERATOR. SETELAH DATA TERKUMPUL, DAPAT DILAKUKAN PERHITUNGAN DAN ANALISIS DARI SEBERAPA BESAR REGULASI TEGANGAN PADA GENERATOR PLTA TES DAN SEBERAPA PENGARUH NYA AVR PADA GENERATOR DI PLTA TES. NILAI REGULASI TEGANGAN TERTINGGI YAITU SEBESAR 4,80 % PADA PADA GENERATOT UNIT 3, 4,55 % PADA GENERATOR UNIT 4, DAN 1 % PADA GENERATOR UNIT 7 DENGAN NILAI TEGANGAN TERMINAL MASING-MASING 6580 V, 6596 V, DAN 6703 V. SEMAKIN RENDAH TEGANGAN TERMINAL MAKA SEMAKIN TINGGI REGULASI TEGANGAN. KETIKA ARUS BEBAN TURUN, KEMUDIAN KECEPATAN PUTAR GENERATOR MENJADI NAIK, MAKA AVR MULAI BEKERJA DENGAN CARA MENURUNKAN ARUS EKSITASI NYA AGAR TIDAK TERJADI OVER VOLTAGE, BEGITUPUN SEBALIKNYA. AVR PADA GENERATOR DI PLTA TES SANGAT BERPENGARUH PADA GENERATOR PLTA TES DAN BEKERJA DENGAN BAIK KARENA TEGANGAN TERMINAL GENERATOR TIDAK MENGALAMI KENAIKAN DAN PENURUNAN SECARA SIGNIFIKAN DAN REGULASI TEGANGANNYA TETAP DI BAWAH BATAS MAKSIMAL YAITU 5%.
Item Type: | Thesis (S1) |
---|---|
Uncontrolled Keywords: | AVR, PLTA, VOLTAGE, REGULATION |
Divisions: | Fakultas Teknik > Teknik Elektro S1 |
Depositing User: | M. Erdiansyah |
Date Deposited: | 10 Sep 2022 07:15 |
Last Modified: | 10 Sep 2022 07:15 |
URI: | https://etd.umy.ac.id/id/eprint/33771 |