MUHAMMAD DIRGA SETIAWAN (2022) PENYEIMBANGAN BEBAN TRAFO DITRIBUSI SATU FASA UNTUK MENGURANGI ARUS PADA SALURAN NETRAL JARINGAN TEGANGAN RENDAH DI PT. PLN (). S1 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (3MB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (849kB)
Abstrak.pdf
Restricted to Registered users only
Download (782kB)
Bab I.pdf
Download (964kB)
Bab II.pdf
Restricted to Registered users only
Download (5MB)
Bab III.pdf
Restricted to Registered users only
Download (807kB)
Bab IV.pdf
Restricted to Registered users only
Download (9MB)
Bab V.pdf
Restricted to Registered users only
Download (387kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (722kB)
Lampiran.pdf
Restricted to Registered users only
Download (1MB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (834kB)
Full Text.pdf
Restricted to Repository staff only
Download (3MB)
Abstract
SALAH SATU PENYEBAB TERJADINYA RUGI-RUGI DAYA KARENA ADANYA FAKTOR KETIDAKSEIMBANGAN BEBAN PADA SUATU SISTEM DISTRIBUSI TENAGA LISTRIK. RUGI-RUGI DAYA ADALAH SUATU KONDISI BESARAN ENERGI YANG DI DISTRIBUSIKAN TIDAK SAMA DENGAN ENERGI YANG AKAN DIDAPATKAN OLEH PELANGGAN. FAKTANYA SUATU SISTEM DISTRIBUSI SATU FASA SELALU DALAM KEADAAN TIDAK SEIMBANG YANG MANA KETIKA SUATU SISTEM DISTRIBUSI TENAGA LISTRIK BEKERJA MELAKUKAN PEMBAGIAN PEMBEBANAN TRAFO YANG AWALNYA SEIMBANG, ADA SEBUAH KONDISI YANG TIDAK BISA TERHINDAR DILAPANGAN SEPERTI ADA KETIDAKSEREMPAKAN PENYALAAN BEBAN, PEMASANGAN DAN PEMBONGKARAN BARU YANG TIDAK TERMONITORING. INI YANG AKAN MEMBUAT MENGALIRNYA ARUS PADA JARINGAN KAWAT PENGHANTAR NETRAL, JIKA TIDAK DICEGAH INI AKAN MENGHASILKAN KERUGIAN DAYA YANG BISA BERDAMPAK KE PIHAK PLN SECARA TEKNIS DAN SECARA MATERI. BERKAITAN DENGAN HAL INI DILAKUKAN ANALISA UNTUK PENELITIAN PROYEK TUGAS AKHIR DENGAN STUDI KASUS DIPILIH LOKASI DI PT. PLN (PERSERO) RAYON BANTUL. DENGAN PENGAMATAN PADA 5 BUAH TRAFO SATU FASA UNTUK MENGURANGI NILAI ARUS PADA PENGHANTAR NETRAL SAAT TERJADI KETIDAKSEIMBANGAN BEBAN LEWAT PENYEIMBANGAN PEMINDAHAN SAMBUNGAN RUMAH. MAKA DIPEROLEH NILAI UNTUK MENEKAN RUGI-RUGI DAYA AKIBAT ADANYA ARUS MENGALIR PADA PENGHANTAR NETRAL SETELAH MELAKUKAN PENYEIMBANGAN ADALAH SEBESAR 1,698 KWH/HARI DAN 36,09 KWH/BULAN, KEMUDIAN NILAI KERUGIAN MATERI AKIBAT MENGALIRNYA ARUS PADA PENGHANTAR NETRAL SETELAH DILAKUKAN PENYEIMBANGAN ADALAH SEBESAR RP. 2.295/HARI DAN RP. 48.793/BULAN. JIKA DILIHAT PENYEIMBANGAN DALAM HAL INI MAMPU DAPAT MENEKAN RUGI-RUGI DAYA, RUGI-RUGI TEKNIK DAN NONTEKNIK.
Item Type: | Thesis (S1) |
---|---|
Uncontrolled Keywords: | NEUTRAL CURRENT, LOAD BALANCING, UNBALANCE LOAD, POWER LOSS, TRANSFORMER. |