WILGAN ARYA PUTRA PRATAMA (2022) ANALISIS PENGGUNAAN RELAY DIFFERENTIAL SEBAGAI PROTEKSI PADA TRANSFORMATOR DAYA 60 MVA DI GARDU INDUK BANTUL. S1 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (886kB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (613kB)
Abstrak.pdf
Restricted to Registered users only
Download (38kB)
Bab I.pdf
Download (109kB)
Bab II.pdf
Restricted to Registered users only
Download (361kB)
Bab III.pdf
Restricted to Registered users only
Download (241kB)
Bab IV.pdf
Restricted to Registered users only
Download (1MB)
Bab V.pdf
Restricted to Registered users only
Download (40kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (90kB)
Lampiran.pdf
Restricted to Registered users only
Download (1MB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (223kB)
Full Text.pdf
Restricted to Repository staff only
Download (4MB)
Abstract
SISTEM PROTEKSI MERUPAKAN KESATUAN YANG TIDAK DAPAT DIPISAHKAN DALAM SISTEM TENAGA LISTRIK. TERDAPAT BERBAGAI MACAM GANGGUAN SALAH SATUNYA GANGGUAN PADA TRANSFORMATOR DAYA YAITU GANGGUAN INTERNAL DAN EKSTERNAL, SEHINGGA SISTEM PROTEKSI SANGAT DIPERLUKAN UNTUK MENDETEKSI ADANYA GANGGUAN DAN JUGA MENGURANGI TERJADINYA KERUSAKAN PADA TRANSFORMATOR. PROTEKSI UTAMA PADA TRANSFORMATOR DAYA YAITU RELAY DIFFERENTIAL. PADA PENELITIAN INI MEMBAHAS TENTANG PERBANDINGAN PERHITUNGAN SETTING RELAY DIFFERENTIAL SECARA TEORI MENGGUNAKAN PERHITUNGAN MATEMATIS DENGAN DATA AKTUAL YANG DIDAPAT PADA TRANSFORMATOR GARDU INDUK BANTUL. METODE YANG DIGUNAKAN PADA PENELITIAN INI PENGAMBILAN DATA DI GARDU INDUK 150 KV BANTUL. SETELAH ITU MELAKUKAN PERHITUNGAN MANUAL MENGGUNAKAN RUMUS MATEMATIS DAN DISIMULASIKAN MENGGUNAKAN SOFTWARE ETAP 12.6.0. ARUS SETTING PADA TRANSFORMATOR I, II, DAN III YANG DIDAPAT OLEH PERHITUNGAN MANUAL SEBESAR 0,4 A. TERDAPAT SELISIH ANTARA ARUS SETTING PADA DATA AKTUAL GARDU INDUK BANTUL PADA TRANSFORMATOR I DAN II SEBESAR 0,3 A DAN PADA TRANSFORMATOR III SEBESAR 0,23 A. RELAY DIFFERENTIAL AKAN BEKERJA KETIKA ARUS YANG MENGALIR MELEBIHI ARUS SETTING PADA SAAT TERJADI GANGGUAN DI DAERAH PENGAMAN, SETELAH ITU RELAY DIFFERENTIAL AKAN MEMERINTAHKAN PMT UNTUK TRIP DAN MEMUTUSKAN JARINGAN.
Item Type: | Thesis (S1) |
---|---|
Uncontrolled Keywords: | PROTECTION SYSTEM, TRANSFORMER, DIFFERENTIAL RELAY, ETAP 12.6.0 |
Divisions: | Fakultas Teknik > Teknik Elektro S1 |
Depositing User: | Eko Kurnawan |
Date Deposited: | 31 Aug 2022 09:33 |
Last Modified: | 31 Aug 2022 09:33 |
URI: | https://etd.umy.ac.id/id/eprint/34601 |