GAMEL ABDILLAH (2022) ANALISIS PERFORMA GENERATOR SINKRON DI PT.PLN (PERSERO) PLTA TES BENGKULU. S1 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (381kB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (2MB)
Abstrak.pdf
Restricted to Registered users only
Download (29kB)
Bab I.pdf
Download (208kB)
Bab II.pdf
Restricted to Registered users only
Download (594kB)
Bab III.pdf
Restricted to Registered users only
Download (468kB)
Bab IV.pdf
Restricted to Registered users only
Download (603kB)
Bab V.pdf
Restricted to Registered users only
Download (205kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (44kB)
Lampiran.pdf
Restricted to Registered users only
Download (1MB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (431kB)
Full Text.pdf
Restricted to Repository staff only
Download (2MB)
Abstract
GENERATOR LISTRIK ADALAH MESIN YANG DIGUNAKAN UNTUK MENGHASILKAN ENERGI LISTRIK DARI SUMBER ENERGI MEKANIK. PRINSIP KERJA DARI GENERATOR LISTRIK ADALAH INDUKSI ELEGTROMAGNETIK. ENERGI MEKANIK ADALAH DAYA MASUKAN PADA GENERATOR, SEDANGKAN ENERGI LISTRIK ADALAH DAYA KELUARAN PADA GENERATOR. DAYA MASUKAN PADA GENERATOR TERSEBUT DIHASILKAN OLEH TURBIN AIR, KARENA TURBIN DAN GENERATOR DI PLTA TIDAK DAPAT DIPISAHKAN DAN SALING BEKERJA SAMA UNTUK MENGHASILKAN ENERGI LISTRIK. PERFORMA GENERATOR AKAN MENGALAMI PENURUNAN FUNGSI AKIBAT BEBERAPA FAKTOR SEPERTI DERATING (PENURUNAN BEBAN) ATAU TRIP (UNIT SHUTDOWN), FAKTOR LAMANYA PEMELIHARAAN, KESALAHAN DALAM PENGOPERASIAN DAN PERAWATAN SERTA FAKTOR LAIN. SETELAH MENGUMPULKAN DATA YANG DIPERLUKAN, UNTUK MENGETAHUI PERFORMA DARI GENERATOR UNIT 5 DAN GENERATOR UNIT 7 PLTA TES, MAKA DILAKUKAN PERHITUNGAN REGULASI TEGANGAN PADA GENERATOR UNIT 5 DAN GENERATOR UNIT 7 PLTA TES. TEGANGAN TERMINAL SANGAT MEMPENGARUHI REGULASI TEGANGAN, KETIKA TEGANGAN TERMINAL LEBIH BESAR DARI PADA TEGANGAN TANPA BEBAN, MAKA REGULASI TEGANGAN AKAN MEMILIKI NILAI MINUS (-) BEGITU JUGA SEBALIKNYA KETIKA TEGANGAN TERMINAL LEBIH KECIL DARI TEGANGAN TANPA BEBAN MAKA REGULASI TEGANGANNYA TIDAK BERNILAI MINUS (-). REGULASI TEGANGAN GENERATOR UNIT 5 YANG TERTINGGI ADALAH 5,48
Item Type: | Thesis (S1) |
---|---|
Uncontrolled Keywords: | PLTA, voltage regulation, Derating (load reduction), Trip (unit shutdown) |
Divisions: | Fakultas Teknik > Teknik Elektro S1 |
Depositing User: | M. Erdiansyah |
Date Deposited: | 15 Dec 2023 09:18 |
Last Modified: | 15 Dec 2023 09:18 |
URI: | https://etd.umy.ac.id/id/eprint/35618 |