REZA (2022) ANLISIS GANGGUAN DI GARDU INDUK 150 KV CAWANG TERHADAP KINERJA SISTEM PROTEKSI. S1 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (547kB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (1MB)
Abstrak.pdf
Restricted to Registered users only
Download (17kB)
Bab I.pdf
Download (86kB)
Bab II.pdf
Restricted to Registered users only
Download (609kB)
Bab III.pdf
Restricted to Registered users only
Download (140kB)
Bab IV.pdf
Restricted to Registered users only
Download (657kB)
Bab V.pdf
Restricted to Registered users only
Download (15kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (14kB)
Lampiran.pdf
Restricted to Registered users only
Download (1MB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (283kB)
Full Text.pdf
Restricted to Repository staff only
Download (5MB)
Abstract
INTISARI PADA SUATU SISTEM PENYALURAN TENAGA LISTRIK, ADA POTENSI TERJADINYA GANGGUAN YANG DISEBABKAN OLEH BANYAK FAKTOR. GANGGUAN YANG TERJADI BISA BERUPA DARI ALAM SEPERTI KERUSAKAN PADA PEMBANGKIT, KAWAT PENGHANTAR PUTUS, GANGGUAN PADA SALURAN TRANSMISI, GANGGUAN HUBUNGAN SINGKAT, DAN LAINNYA. DENGAN ADANYA GANGGUAN YANG TIDAK BISA DI PREDIKSI, MAKA DIBUTUHKAN SISTEM PROTEKSI ATAU SUATU PENGAMAN PERALATAN LISTRIK. SISTEM PROTEKSI MEMPUNYAI FUNGSI UNTUK MENGHINDARI TERJADINYA KERUSAKAN PADA PERALATAN-PERALATAN GARDU INDUK. SALAH SATU KOMPONEN UTAMA YANG TERDAPAT PADA GI ADALAH TRANSFORMATOR TENAGA. TRANSFORMATOR TENAGA MERUPAKAN SALAH SATU PERALATAN PENTING PADA PENYALURAN TENAGA LISTRIK YANG DIMANA TRANSFOMARTOR INI MENYALURKAN ENERGI LISTRIK KE KONSUMEN BAIK PADA JARINGAN TEGANGAN TINGGI ( JTT ), JARINGAN TEGANGAN MENENGAH ( JTM ), DAN JARINGAN TEGANGAN RENDAH ( JTR ). UNTUK MENGATASI KERUSAKAN DARI TRANSFORMATOR TENAGA, DIPERLUKAN ADANYA PEMASANGAN RELE-RELE PROTEKSI YANG BISA MENGENALI KONDISI ABNORMAL PADA SISTEM TENAGA LISTRIK. PENELITIAN INI BERTUJUAN UNTUK MENENTUKAN JENIS GANGGUAN YANG DAPAT MENYEBABKAN AKTIFNYA SISTEM PROTEKSI YANG TELAH TERPASANG PADA GARDU INDUK DAN MENGGUNAKAN SOFTWARE ETAP 12.6.0 UNTUK MENGETAHUI HASIL SIMULASI YANG DIJALANKAN. DALAM MENGAMANKAN DARI ADANYA GANGGUAN HUBUNG SINGKAT YANG TERJADI PADA TRANSFORMATOR I, II, III, DAN IV DI GARDU INDUK 150KV CAWANG, MAKA OVER CURRENT RELAY (OCR) BEKERJA MEMBERI SINYAL KEPADA PMT UNTUK TRIP. PADA SAAT TERJADI GANGGUAN DI SALAH SATU TRANSFORMATOR SISI 20KV YANG MEMILIKI TEGANGAN SEBESAR 13,875KA, MAKA WAKTU YANG DIBUTUHKAN UNTUK MEMUTUS ARUS ADALAH 0,851 S. DAPAT DIKATAKAN OCR BEKERJA SECARA BAIK DALAM MENGAMANKAN TRANSFORMATOR DARI ADANYA GANGGUAN YANG TERJADI. KATA KUNCI : GARDU INDUK, TRANSFORMATOR, PROTEKSI, OVER CURRENT RELAY
Item Type: | Thesis (S1) |
---|---|
Uncontrolled Keywords: | SUBSTATIONS, TRANSFORMER, PROTECTION, OVER CURRENT RELAY |
Divisions: | Fakultas Teknik > Teknik Elektro S1 |
Depositing User: | M. Erdiansyah |
Date Deposited: | 18 Dec 2023 06:09 |
Last Modified: | 18 Dec 2023 06:09 |
URI: | https://etd.umy.ac.id/id/eprint/35750 |