ANALISIS PENGGUNAAN LIGHTNING ARRESTER SEBAGAI PROTEKSI PADA GARDU INDUK BANTUL 150KV

ARKAN FAUZAN TSANY K. (2022) ANALISIS PENGGUNAAN LIGHTNING ARRESTER SEBAGAI PROTEKSI PADA GARDU INDUK BANTUL 150KV. S1 thesis, Universitas Muhammadiyah Yogyakarta.

[thumbnail of Halaman Judul] Text (Halaman Judul)
Halaman Judul.pdf

Download (674kB)
[thumbnail of Lembar Pengesahan] Text (Lembar Pengesahan)
Lembar Pengesahan.pdf
Restricted to Registered users only

Download (833kB)
[thumbnail of Abstrak] Text (Abstrak)
Abstrak.pdf
Restricted to Registered users only

Download (10kB)
[thumbnail of Bab I] Text (Bab I)
Bab I.pdf

Download (116kB)
[thumbnail of Bab II] Text (Bab II)
Bab II.pdf
Restricted to Registered users only

Download (762kB)
[thumbnail of Bab III] Text (Bab III)
Bab III.pdf
Restricted to Registered users only

Download (280kB)
[thumbnail of Bab IV] Text (Bab IV)
Bab IV.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of Bab V] Text (Bab V)
Bab V.pdf
Restricted to Registered users only

Download (10kB)
[thumbnail of Daftar Pustaka] Text (Daftar Pustaka)
Daftar Pustaka.pdf
Restricted to Registered users only

Download (102kB)
[thumbnail of Lampiran] Text (Lampiran)
Lampiran.pdf
Restricted to Registered users only

Download (442kB)
[thumbnail of Naskah Publikasi] Text (Naskah Publikasi)
Naskah Publikasi.pdf
Restricted to Registered users only

Download (300kB)
[thumbnail of Full Text] Text (Full Text)
Full Text.pdf
Restricted to Repository staff only

Download (4MB)

Abstract

LIGHTNING ARRESTER MERUPAKAN PERALATAN YANG PENTING DALAM PERLINDUNGAN PADA GARDU INDUK DARI TEGANGAN TINGGI SEBAGAI PEMBATAS SWITCHING DAN LONJAKAN PETIR JIKA TERKENA TEGANGAN BERLEBIH, HAL TERSEBUT AKAN MENGAKIBATKAN TEGANGAN DIPOTONG LALU DIALIRKAN KE TANAH. PENENTUAN POSISI OPTIMUM LIGHTNING ARRESTER (ARRESTER) SANGAT BERPENGARUH DALAM PERLINDUNGAN SISTEM TENAGA LISTRIK DAN DAPAT MEMINIMALISIR RESIKO KEGAGALAN. METODE YANG DIGUNAKAN PADA PENELITIAN INI YAITU MELAKUKAN PENGUMPULAN DATA BERUPA JARAK ARRESTER, TEGANGAN SISTEM MAKSIMUM, DAN TEGANGAN IMPULS LALU DILANJUTKAN DENGAN MELAKUKAN SIMULASI PADA APLIKASI ETAP 12.6. DARI HASIL PERHITUNGAN DIDAPAT JARAK IDEAL ARRESTER DENGAN TRANSFORMATOR ADALAH 7,7 METER, NAMUN JARAK YANG TERPASANG PADA GI BANTUL ADALAH 5 METER. PENEMPATAN ARRESTER PADA GI BANTUL SUDAH DALAM KATEGORI AMAN DIKARENAKAN MASIH DALAM BATAS JARAK IDEAL. BERDASARKAN DARI HASIL SIMULASI DENGAN MENGGUNAKAN SOFTWARE ETAP, JARAK IDEAL YANG DIDAPAT ANTARA ARRESTER DENGAN TRANSFORMATOR PADA GI BANTUL 150KV ADALAH 5 METER SESUAI DENGAN JARAK YANG ADA DI GI BANTUL, SEDANGKAN UNTUK JARAK MAKSIMUM PENEMPATAN ARRESTER YANG TELAH DISESUAIKAN DENGAN SPLN 1978:4 DAN IEC 1958 ADALAH 28,5 METER. PENEMPATAN ARRESTER DI GI BANTUL 150KV MEMENUHI STANDAR YANG TELAH DITENTUKAN PADA JARAK AMAN DARI PENGARUH SAMBARAN PETIR. NILAI TEGANGAN PENGENAL ARRESTER YANG TERHUBUNG DENGAN TRANSFORMATOR 1 PADA GI BANTUL DIDAPAT 132KV YANG MANA MERUPAKAN TEGANGAN YANG SUDAH MULAI BISA TERPOTONG OLEH ARRESTER. DIDAPAT HASIL TEGANGAN IMPULS MAKSIMAL 551KV DAN UNTUK RATING SPESIFIKASI ARRESTER ADALAH 669KV. BERDASARKAN PEMILIHAN SPESIFIKASI PADA ARRESTER YANG TERPASANG PADA GI BANTUL 150KV TERMASUK DALAM KATEGORI AMAN DIKARENAKAN TEGANGAN IMPULS MAKSIMALNYA DIBAWAH DARI NILAI RATING ARRESTER.

Item Type: Thesis (S1)
Uncontrolled Keywords: ARRESTER, IMPULSE, ETAP 12.6
Divisions: Fakultas Teknik > Teknik Elektro S1
Depositing User: M. Erdiansyah
Date Deposited: 18 Dec 2023 06:52
Last Modified: 18 Dec 2023 06:52
URI: https://etd.umy.ac.id/id/eprint/35815

Actions (login required)

View Item
View Item