AZKA AZKIYA (2022) ANALISIS PENGARUH KETIDAKSEIMBANGAN BEBAN TERHADAP RUGI-RUGI DAYA DAN PENYEIMBANGAN BEBAN DENGAN METODE SATU TITIK WAKTU PADA TRANSFORMATOR DISTRIBUSI GUTI DI PT. PLN (PERSERO) UP3 KOTA TASIKMALAYA. S1 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (2MB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (2MB)
Abstrak.pdf
Restricted to Registered users only
Download (34kB)
Bab I.pdf
Download (79kB)
Bab II.pdf
Restricted to Registered users only
Download (543kB)
Bab III.pdf
Restricted to Registered users only
Download (59kB)
Bab IV.pdf
Restricted to Registered users only
Download (437kB)
Bab V.pdf
Restricted to Registered users only
Download (132kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (11kB)
Lampiran.pdf
Restricted to Registered users only
Download (657kB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (340kB)
Full Text.pdf
Restricted to Repository staff only
Download (6MB)
Abstract
KETERSEDIAAN TENAGA LISTRIK MERUPAKAN KEBUTUHAN POKOK DALAM MENDUKUNG PERKEMBANGAN TEKNOLOGI ATAUPUN BAGI KEHIDUPAN MANUSIA SEHARI-HARI. KETERSEDIAAN TENAGA LISTRIK HARUS DIPERTAHANKAN KESINAMBUNGANNYA, DALAM HAL INI PT. PLN (PERSERO) SEBAGAI PERUSAHAAN PENYEDIA ENERGI LISTRIK YANG DIGUNAKAN MASYARAKAT INDONESIA HARUS MENJAMIN KUALITAS PENDISTRIBUSIAN ENERGI LISTRIK AGAR LISTRIK DAPAT TERSALURKAN MENUJU KONSUMEN. DALAM PENDISTRIBUSIAN TENAGA LISTRIK AWALNYA BEBAN DIBAGI SECARA MERATA DISETIAP FASA NYA, NAMUN KARENA WAKTU PENGOPRASIAN BEBAN-BEBAN TERSEBUT YANG TIDAK SEREMPAK, MAKA MENIMBULKAN KETIDAKSEIMBANGAN BEBAN YANG MENYEBABKAN MENGALIRNYA ARUS PADA NETRAL DAN RUGI DAYA PADA PENGHANTAR NETRAL. DATA YANG DIGUNAKAN PADA PENELITIAN INI DIDAPATKAN DARI HASIL PENGUKURAN TRANSFORMATOR DISTRIBUSI GUTI YANG BERKAPASITAS 250 KVA MILIK PT. PLN (PERSERO) UP3 KOTA TASIKMALAYA. KEMUDIAN AKAN DILAKUKAN BEBARAPA PERHITUNGAN GUNA MENGETAHUI PERSENTASE KETIDAKSEIMBANGAN BEBAN ANTAR FASA, PERSENTASE ARUS NETRAL TERHADAP ARUS BEBAN, RUGI DAYA PENGHANTAR NETRAL, RUGI ENERGI DAN KERUGIAN FINANSIAL SEBELUM DAN SESUDAH PENYEIMBANGAN BEBAN. PERHITUNGAN INI AKAN DIJADIKAN SEBAGI DASAR ANALISIS PENGARUH KETIDAKSEIMBANGAN BEBAN TERHADAP RUGI-RUGI DAYA DAN KERUGIAN FIANSIAL YANG DIALAMI PRODUSEN SEBELUM DAN SESUDAH PENYEIMBANGAN. BERDASARKAN PERHITUNGAN YANG TELAH DILAKUKAN DIPEROLEH PERSENTASE KETIDAKSEIMBANGAN BEBAN SEBESAR 33% PADA KONDISI LWBP DAN 34% PADA KONDISI WBP, DIPEROLEH JUGA NILAI PERSENTASE ARUS NETRAL TERHADAP ARUS BEBAN SEBESAR 38,6% PADA KONDISI LWBP DAN 44,8% PADA KONDISI WBP. NILAI RUGI DAYA PENGHANTAR NETRAL DIDAPATKAN SEBESAR 1,825 KW PADA KONDISI LWBP DAN 4,056 KW PADA KONDISI WBP, DENGAN TOTAL RUGI ENERGI SEBESAR 1.581,72 KWH/BULAN DAN KERUGIAN FINANSIAL SEBESAR RP. 2.688.180/BULAN SEBELUM PENYEIMBANGAN BEBAN. PENYEIMBANGAN BEBAN DILAKUKAN DENGAN TUJUAN MEMINIMALISIR NILAI PERSENTASE KETIDAKSEIMBANGAN BEBAN YANG TERJADI, SETELAH DILAKUKAN PENYEIMBANGAN BEBAN DIDAPATKAN NILAI PERSENTASE KETIDAKSEIMBANGAN BEBAN SEBESAR 9% PADA KONDISI LWBP DAN 5% PADA KONDISI WBP, PENURUNAN JUGA TERJADI PADA NILAI PERSENTASE ARUS NETRAL TERHADAP ARUS BEBAN DIDAPATKAN SEBESAR 19% PADA KONDISI LWBP DAN 20% PADA KONDISI WBP. NILAI RUGI DAYA PENGHANTAR NETRAL DIDAPATKAN SEBESAR 0,343 KW PADA KONDISI LWBP DAN 0,439 PADA KONDISI WBP, DENGAN TOTAL RUGI ENERGI SEBESAR 469,2 KWH/BULAN DAN KERUGIAN FINANSIAL SEBESAR RP. 797.419/BULAN. ARTINYA DENGAN DILAKUKANNYA PENYEIMBANGAN BEBAN TOTAL NILAI ENERGI YANG DAPAT DISELAMATKAN SEBEESAR 1.112,52 KWH/BULAN DAN PENGHEMATAN BIAYA DARI KERUGIAN FINANSIAL SEBESAR RP. 1.890.761/BULAN.
Item Type: | Thesis (S1) |
---|---|
Uncontrolled Keywords: | DISTRIBUTION TRANSFORMER, LOAD UNBALANCE, NEUTAL CURRENT, POWER LOSS AND LOAD BALANCING |
Divisions: | Fakultas Teknik > Teknik Elektro S1 |
Depositing User: | M. Erdiansyah |
Date Deposited: | 18 Dec 2023 07:10 |
Last Modified: | 18 Dec 2023 07:10 |