HILGAN BANGSAWAN (2022) ANALISIS THERMOVISI UNTUK MENEMUKAN HOTPOINT PADA GARDU INDUK PLN BANGKO. S1 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (722kB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (1MB)
Abstrak.pdf
Restricted to Registered users only
Download (56kB)
Bab I.pdf
Download (130kB)
Bab II.pdf
Restricted to Registered users only
Download (509kB)
Bab III.pdf
Restricted to Registered users only
Download (272kB)
Bab IV.pdf
Restricted to Registered users only
Download (1MB)
Bab V.pdf
Restricted to Registered users only
Download (122kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (176kB)
Lampiran.pdf
Restricted to Registered users only
Download (539kB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (290kB)
Full Text.pdf
Restricted to Repository staff only
Download (4MB)
Abstract
PENGUKURAN MENGGUNAKAN THERMOVISI MERUPAKAN SALAH SATU PEMELIHARAAN YANG DILAKUKAN TERHADAP PERALATAN GARDU INDUK. THERMOVISI BERFUNGSI UNTUK MEMVISUALKAN PANAS DAN MENDETEKSI TITIK PANAS (HOT POINT) PADA PERALATAN DENGAN VISUAL INFRARED. PENGUKURAN MENGGUNAKAN THERMOVISI JUGA MEMILIKI KELEMAHAN DALAM MEMPROSES TEMPERATUR YANG SEBENARNYA. DIKARENAKAN, NILAI EMISIVITAS PADA OBJEK YANG TELAH DI UKUR BERVARIASI ANTARA 0 HINGGA 1. PENELITIAN INI MEMBAHAS TENTANG METODE VALIDASI DALAM MENGUJI PENGUKURAN YANG TELAH DILAKUKAN APAKAH MEMILIKI AKURASI DAN PRESISI YANG BAIK DENGAN MENGGUNAKAN PERHITUNGAN MATEMATIS. METODE YANG DI GUNAKAN YAITU MENCARI REFERENSI PENELITIAN, PENGUMPULAN DATA PENELITIAN DI LOKASI, ANALISIS DAN PERHITUNGAN MATEMATIS. PENELITIAN BERFOKUS PADA BAGIAN KLEM DAN KONDUKTOR BAY TRAFO SERTA DILAKUKAN PENGUKURAN SETIAP SEMINGGU SATU KALI PADA BULAN MARET DAN APRIL 2022. HASIL DARI PENELITIAN INI MENUNJUKKAN RATA-RATA DARI PENGUKURAN YANG TELAH DI LAKUKAN DAN TERJADI PENURUNAN TEMPERATUR DARI BULAN MARET 2022 KE BULAN APRIL 2022, PENURUNAN INI BISA DISEBABKAN OLEH BEBERAPA FATOR ANTARA LAIN FAKTOR LINGKUNGAN/CUACA DAN KENAIKAN BEBAN LISTRIK. NILAI EMISIVITAS PADA TITIK PERALATAN DI BAY TRAFO GARDU INDUK BERBEDA-BEDA MESKIPUN MENGGUNAKAN 1 JENIS MATERIAL, HAL INI DIKARENAKAN BEBERAPA FAKTOR. MELALUI PERHITUNGAN MATEMATIS DIDAPAT NILAI AKURASI SEBESAR 91,66% PADA BULAN MARE 2022 DAN 91,92% PADA BULAN APRIL 2022, SERTA NILAI PRESISI SEBESAR 5,22% PADA BULAN MARET 2022 DAN 4,39% PADA BULAN APRIL 2022