FANDIMAS GAGAH PRATAMA (2022) PENGARUH POROSITAS TANGKI TERHADAP EFISIENSI PENGUMPUL ENERGI TERMAL KUMULATIF PADA PEMANAS AIR TENAGA SURYA TIPE AKTIF YANG MELIBATKAN PARAFFIN WAX DI DALAM TANGKI. S1 thesis, Universitas Muhammadiyah Yogyakarta.
Halaman Judul.pdf
Download (589kB)
Lembar Pengesahan.pdf
Restricted to Registered users only
Download (340kB)
Abstrak.pdf
Restricted to Registered users only
Download (49kB)
Bab I.pdf
Download (104kB)
Bab II.pdf
Restricted to Registered users only
Download (343kB)
Bab III.pdf
Restricted to Registered users only
Download (754kB)
Bab IV.pdf
Restricted to Registered users only
Download (620kB)
Bab V.pdf
Restricted to Registered users only
Download (9kB)
Daftar Pustaka.pdf
Restricted to Registered users only
Download (116kB)
Lampiran.pdf
Restricted to Registered users only
Download (810kB)
Naskah Publikasi.pdf
Restricted to Registered users only
Download (1MB)
Full Text.pdf
Restricted to Repository staff only
Download (3MB)
Abstract
PEMANAS AIR TENAGA SURYA (PATS) ADALAH ALAT PEMANAS AIR YANG MEMANFAATKAN ENERGI MATAHARI SEBAGAI SUMBER ENERGI. PENELITIAN TENTANG PATS YANG BERISI PHASE CHANGE MATERIAL (PCM) SECARA OUTDOOR MEMILIKI KESULITAN DALAM MENGEVALUASI PERUBAHAN PARAMETER TERHADAP KINERJA TERMAL. SALAH SATU PARAMETER KINERJA TERMAL PATS ADALAH EFISIENSI PENGUMPULAN ENERGI TERMAL KUMULATIF. PARAMETER INI ADALAH PERBANDINGAN ANTAR ENERGI YANG BERGUNA DAN ENERGI MASUK DI KOLEKTOR. PENELITIAN TENTANG KARAKTERISTIK EFISIENSI PENGUMPULAN ENERGI TERMAL PADA TANGKI PATS TIPE AKTIF BERISI PARAFFIN WAX DENGAN VARIASI POROSITAS TANGKI MENGGUNAKAN SUSUNAN KAPSUL TIPE TUMBUK BELUM PERNAH DILAKUKAN. TUJUAN DARI PENELITIAN UNTUK MEMPEROLEH PERILAKU EVOLUSI TEMPERATUR HEAT TRANSFER FLUID (HTF) MASUK DAN KELUAR TANGKI DENGAN VARIASI POROSITAS TANGKI DAN MENDAPATKAN PENGARUH PERUBAHAN POROSITAS TANGKI TERHADAP EFISIENSI PENGUMPULAN KUMULATIF DI DALAM TANGKI.
PENELITIAN INI DILAKUKAN DENGAN MENGGUNAKAN SISTEM PATS-PCM METODE INDOOR DENGAN SUSUNAN KAPSUL TIPE TUMBUK YANG BERISI PARAFFIN WAX SEBAGAI PCM. SISTEM PATS DILENGKAPI DENGAN SOLAR SIMULATOR UNTUK MENSUPLAI HEAT FLUX SEBESAR 1000 W/M?2;. KAPSUL YANG DIGUNAKAN PADA PENELITIAN INI ADALAH 13, 17 DAN 21 BUAH. NILAI POROSITAS TANGKI UNTUK TIAP-TIAP VARIASI ADALAH 89,00 %, 85,62%, DAN 82,23%. TERMOKOPEL YANG DIGUNAKAN PADA PENELITIAN INI BERJUMLAH 24 BUAH. DATA TEMPERATUR HTF YANG ADA DI DALAM TANGKI PENYIMPANAN DIREKAM. ANALISIS DATA DILAKUKAN UNTUK MENGETAHUI EFISIENSI PENGUMPULAN ENERGI TERMAL KUMULATIF DI DALAM TANGKI.
BERDASARKAN HASIL PENELITIAN, DIKETAHUI BAHWA TERDAPAT PENGARUH PERBEDAAN VARIASI POROSITAS TANGKI TERHADAP BESAR KECILNYA EFISIENSI KUMULATIF PENGUMPULAN ENERGI. KAPSUL 13, 17 DAN 21 DENGAN POROSITAS TIAP VARIASI 89,00 %, 85,62%, DAN 82,23% MASING-MASING MENGHASILKAN EFISIENSI KUMULATIF RATA-RATA SEBESAR 42,99%, 53,30%, DAN 58,25%. SEMAKIN KECIL POROSITAS TANGKI, EFISIENSI PENGUMPULAN ENERGI TERMAL KUMULATIF PENGUMPULAN SEMAKIN BESAR.