ANALISIS PERFORMA PADA GENERATOR DAYA 80 MVA UNIT 1 DAN 4 PT PLN (PERSERO) UPK BUKIT ASAM

Darma Adi Guna Alfat (2021) ANALISIS PERFORMA PADA GENERATOR DAYA 80 MVA UNIT 1 DAN 4 PT PLN (PERSERO) UPK BUKIT ASAM. S1 thesis, Universitas Muhammadiyah Yogyakarta.

[thumbnail of Halaman Judul] Text (Halaman Judul)
Halaman Judul.pdf

Download (516kB)
[thumbnail of Lembar Pengesahan] Text (Lembar Pengesahan)
Lembar Pengesahan.pdf
Restricted to Registered users only

Download (500kB)
[thumbnail of Abstrak] Text (Abstrak)
Abstrak.pdf
Restricted to Registered users only

Download (34kB)
[thumbnail of Bab I] Text (Bab I)
Bab I.pdf

Download (40kB)
[thumbnail of Bab II] Text (Bab II)
Bab II.pdf
Restricted to Registered users only

Download (783kB)
[thumbnail of Bab III] Text (Bab III)
Bab III.pdf
Restricted to Registered users only

Download (229kB)
[thumbnail of Bab IV] Text (Bab IV)
Bab IV.pdf
Restricted to Registered users only

Download (743kB)
[thumbnail of Bab V] Text (Bab V)
Bab V.pdf
Restricted to Registered users only

Download (34kB)
[thumbnail of Daftar Pustaka] Text (Daftar Pustaka)
Daftar Pustaka.pdf
Restricted to Registered users only

Download (32kB)
[thumbnail of Lampiran] Text (Lampiran)
Lampiran.pdf
Restricted to Registered users only

Download (753kB)
[thumbnail of Naskah Publikasi] Text (Naskah Publikasi)
Naskah Publikasi.pdf
Restricted to Registered users only

Download (437kB)
[thumbnail of Full Text] Text (Full Text)
Full Text.pdf
Restricted to Repository staff only

Download (3MB)

Abstract

PT PLN (PERSERO) UPK Bukit Asam units 1 and 4 are Pembangkit Listrik Tenaga Uap (PLTU), each with a capacity of 65 MW. As a large-capacity power plant, it certainly has a large generator capacity too. Generators in generating electrical energy over time the generator will experience a decrease in generator performance. In this study, discussing the performance of power generator units 1 and 4 at PT PLN (PERSERO) UPK Bukit Asam by analyzing several generator performance parameters whether they are in accordance with generator design standards. The results of the study found that at the generator output there is active power, output voltage, output current, reactive power and apparent power. For the highest value on generator unit 1 is 57 MW; 10,93 KV; 3,03 KA; 12,1 MVAR; 58,13 MVA and the lowest value is 39,9 MW; 10,83 KV; 2,13 KA; 2,2 MVAR; 40,18 MVA. The highest value on generator unit 4 is 56,9 MW; 10,90 KV; 3,13 KA; 20,3 MVAR; 59,74 MVA and the lowest value is 41,1 MW; 10,90 KV; 2,17 KA; 7,9 MVAR; 44,16 MVA. From the results of the power factor, the performance of the generator is in a reliable state because the results are not less than the design of the generator which is equal to 0.8. The results of the highest frequency in unit 1 are 50,26 Hz and the lowest is 50,08 Hz, the results from the highest frequency in unit 4 are 50,35 Hz and the lowest is 50,1 Hz, which means that the performance of the frequency generator is reliable because of the results in accordance with the tolerance limit of 5%. The highest unit 1 generator efficiency was 95,95% and the lowest was 66,64%, the highest unit 4 generator efficiency was 92,97% and the lowest was 65,03%.

Item Type: Thesis (S1)
Divisions: Fakultas Teknik > Teknik Elektro S1
Depositing User: Unnamed user with email robi@umy.ac.id
Date Deposited: 15 Dec 2021 02:39
Last Modified: 15 Dec 2021 02:39
URI: https://etd.umy.ac.id/id/eprint/5097

Actions (login required)

View Item
View Item