Fakhriza Atsira Nadhir (2021) REFRIGERATED CENTRIFUGE DENGAN PARAMETER SUHU DAN RPM. S1 thesis, Universitas Muhammadiyah Yogyakarta.
![]() |
Text (Halaman Judul)
Halaman Judul.pdf Download (1MB) |
![]() |
Text (Lembar Pengesahan)
Lembar Pengesahan.pdf Restricted to Registered users only Download (513kB) |
![]() |
Text (Abstrak)
Abstrak.pdf Restricted to Registered users only Download (115kB) |
![]() |
Text (Bab I)
Bab I.pdf Download (82kB) |
![]() |
Text (Bab II)
Bab II.pdf Restricted to Registered users only Download (450kB) |
![]() |
Text (Bab III)
Bab III.pdf Restricted to Registered users only Download (361kB) |
![]() |
Text (Bab IV)
Bab IV.pdf Restricted to Registered users only Download (608kB) |
![]() |
Text (Bab V)
Bab V.pdf Restricted to Registered users only Download (74kB) |
![]() |
Text (Daftar Pustaka)
Daftar Pustaka.pdf Restricted to Registered users only Download (75kB) |
![]() |
Text (Lampiran)
Lampiran.pdf Restricted to Registered users only Download (151kB) |
![]() |
Text (Naskah Publikasi)
Naskah Publikasi.pdf Restricted to Registered users only Download (637kB) |
![]() |
Text (Full Text)
Full Text.pdf Restricted to Repository staff only Download (2MB) |
Abstract
In laboratory examination, a tool is needed to separate a compound having
different molecular weight by utilizing centrifugal force and cold temperature.
Cold temperatures are needed to maintain the quality of a sample such as blood or
urine. For this reason, a Refrigerated Centrifuge is needed which is used to
separate and cool the sample so that the stability of the sample is maintained,
especially in certain samples. In this study, modification of the refrigerated
centrifuge was carried out at the motor speed regulated by PWM using a
microcontroller with a speed setting of 1500-4000 RPM. In setting the
temperature using the evaporator component with the refrigeration cycle method
at temperature settings ranging from 0 to 20 . Based on the results of the 3000
RPM speed measurement, the largest error value is 4%. While the results of
temperature measurements are known to have the largest error value of 6% at a
temperature setting of 10 . It can be concluded that the refrigerated centrifuge can
be used properly and is suitable for use because the error in the temperature and
RPM parameters is still within the tolerance range of ±10%.
Dosen Pembimbing: | Wisnu Kartika, S.T., M.Eng. and Brama Sakti Handoko, S.T | NIDN0512058901, UNSPECIFIED |
---|---|
Item Type: | Thesis (S1) |
Divisions: | Program Vokasi > D3 Teknologi Elektro-medis |
Depositing User: | Unnamed user with email robi@umy.ac.id |
Date Deposited: | 08 Nov 2021 02:10 |
Last Modified: | 08 Nov 2021 02:10 |
URI: | https://etd.umy.ac.id/id/eprint/6596 |
Actions (login required)
![]() |
View Item |